Turn Signal Operation: Notes
When ignition switch is in the ON or START position, power is supplied
- To BCM (body control module) terminal 38
- Through 10A fuse [No. 1, located in fuse block (J/B)]
- To combination meter terminals 41 and 42
- Through 10A fuse [No. 14, located in fuse block (J/B)].
Ground is supplied
- To BCM (body control module) terminal 52
- Through grounds M30 and M66,
- To combination meter terminals 45 and 46
- Through grounds M30 and M66.