Inspection Power Supply And Ground Circuit
- Check Fuse
- Check if wiper and washer fusible link and fuse is blown.
Refer to WIRING DIAGRAM - WIP/R .
OK or NG
- OK: GO TO 2 .
- NG: If fuse or fusible link is blown, be sure to eliminate cause of malfunction before installing new fuse or fusible link, refer to
- For FX35, see POWER DISTRIBUTION .
- For FX45, see POWER DISTRIBUTION .
- Check Power Supply Circuit
- Disconnect BCM connector.
- Check voltage between BCM harness connector terminal and ground.
OK or NG
- OK: GO TO 3 .
- NG: Check harness for open or short between fuse, fusible link and BCM.
- Check Ground Circuit
Check continuity between BCM harness connector M4 terminal 49 (B), 52 (B) and ground.
- 49 (B), 52 (B) - Ground : Continuity should exist
OK or NG
- OK: INSPECTION END
- NG: Repair harness or connector.