Door Warning Lamp
Door waning lamp is controlled by BCM.
When one of the doors is opened, ground is supplied to the BCM terminals 33, 37, 142 and 143.
And then ground is supplied
- to combination meter terminal 3
- from BCM terminal 111.
When power and ground are supplied, the door warning lamp illuminates.