Power Supply And Ground Circuit
Power is supplied at all times
- through 7.5A fuse [No. 24, located in the fuse block (J/B)].
- to combination meter terminal 62.
With the ignition switch in the ON or START position, power is supplied
- through 10A fuse [No. 8, located in the fuse block (J/B)].
- to combination meter terminal 66.
With ignition switch in the ACC or ON position, power is supplied
- through 10A fuse [No. 9, located in the fuse block (J/B)].
- to combination meter terminal 31.
Ground is supplied
- to combination meter terminal 59.
- through body grounds M4, M66 and M147.