  1. Disconnect instrument cluster harness connectors. Using a DVOM connected to ground, measure voltage at appropriate instrument cluster connector terminal, with ignition switch in specified positions. See POWER SUPPLY & GROUND CHECK  table. See Fig 1 . If readings are as specified, go to step  3 . If readings are not as specified, go to next step.
  2. Check fuses No. 12 (10-amp) and No. 30 (10-amp) at instrument panel fuse block. If fuses are open, check for a shorted wiring harness between the instrument cluster and instrument panel fuse block. See WIRING DIAGRAMS  . Replace fuses as necessary. If fuses are okay, go to next step.
  3. Check for continuity to ground at instrument cluster harness connector M34, terminal No. 59 (Black wire). See Fig 1 . If continuity exists, power and ground check is complete. If continuity does not exist, check for an open in power supply between the instrument cluster and instrument panel fuse block fuses No. 12 (10-amp) and No. 30 (10-amp). See WIRING DIAGRAMS  .
POWER SUPPLY & GROUND CHECK

Between Terminal & Ground DVOM Reading
No. 62 (Yellow/Red Wire) (1)
Ignition Switch Position
OFF Battery Voltage
ACC Battery Voltage
ON Battery Voltage
No. 66 (Orange Wire) (1)
Ignition Switch Position
OFF Zero Voltage
ACC Zero Voltage
ON Battery Voltage
No. 59 (Black Wire) (1)
Ignition Switch Position
Any Continuity
(1) Combination meter harness connector M34.
Fig 1: Identifying Instrument Cluster Harness Connector Terminals