Entering Self-Diagnostic Mode
- Turn ignition switch to ON position. Change trip odometer to trip "A". Turn ignition switch to OFF position. While pressing trip odometer reset switch button, turn ignition switch to ON position. Release reset switch button within one second after ignition switch is turned to ON position.
- Press trip odometer reset switch more than 3 times within 5 seconds. All display segments should be illuminated, indicating that diagnostic mode has been entered. See Fig 1
. If any segments are not illuminated, instrument cluster assembly should be replaced.
- If diagnostic mode is entered, go to next step. If diagnostic mode cannot be entered and warning lamps are okay, replace instrument cluster assembly. If diagnostic mode cannot be entered and warning lamps are inoperative, go to POWER SUPPLY & GROUND CIRCUIT CHECK
under SYSTEM TESTS.
- Press odometer/trip meter reset switch. Wait one minute for gauges to stabilize. Gauges should display as illustrated. See Fig 2
. If meters and gauges display as shown in illustration, no malfunction is indicated. Repair instrument cluster concern by symptom. See TROUBLE SHOOTING
. If any gauge does not display as shown in illustration, replace instrument cluster assembly.
Courtesy of NISSAN MOTOR CO., U.S.A.
Courtesy of NISSAN MOTOR CO., U.S.A.