| Heater |
Type |
Fin & Tube type |
| Type |
Tube - Fin 1Way |
| Mode operating method |
Actuator |
| Temperature operating method |
Actuator |
| Evaporator |
Temperature control type |
Evaporator temperature sensor |
| Blower singular |
A/C Output OFF Temperature |
A/C Output ON Temperature |
| Manual control |
1 - 2 speed |
1.5°C (34.7°F) |
3.0°C (37.4°F) |
| 3 - 4 speed |
0.6°C (33.1°F) |
2.1°C (35.8°F) |
| Dual control |
1 - 4 speed |
1.5°C (34.7°F) |
3.0°C (37.4°F) |
| 5 - 6 speed |
1.0°C (33.8°F) |
2.5°C (36.5°F) |
| 7 - 8 speed |
0.6°C (33.1°F) |
2.1°C (35.8°F) |
| Manufacturer |
HVCC (Halla Visteon Climate Control) |