LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2021 >> Ioniq Hybrid SEL >> Repair and Diagnosis >> Brakes >> Anti-Lock Brakes >> ESC/AHB Diagnosis (HEV) >> DTC C2402-01: Motor Electrical >> DTC Information >> DTC Detecting Condition

DTC Information: DTC Detecting Condition

Item Detecting Condition Possible cause
Case 1 DTC Strategy
  • Pump motor fuse open monitoring
  1. Open or short of power supply circuit (ABS1)
  2. Faulty IBAU
Enable Conditions
  • A failure is detected if Battery voltage is below 4V longer than 1sec.
Case 2 DTC Strategy
  • Motor circuit monitoring (open)
Enable Conditions
  • A failure is detected if the motor relay voltage is above 4±0.5V longer than 500 msec during motor relay is off. (This monitoring works after motor relay is switched off longer than 1.8 sec.)
Case 3 DTC Strategy
  • Motor circuit monitoring (short)
Enable Conditions
  • Motor relay voltage is less than specification due to short in motor circuit upon motor relay "ON".1) VMR is below the expected voltage longer than 1second.in
Case 4 DTC Strategy
  • Motor low side open/short (ground loss) monitoring
Enable Conditions
  • If error is recognized after below test.
  1. A failure is detected if VPGND is above 5V longer than 100 msec while motor relay is on.
  2. A failure is detected if VPGND is below 1V longer than 100ms while low side relay is off.
MIL
  • The EBD/RBS/ABS//ESP (ESC)/DBC warning lamps are activated. The AVH warning lamp is activated in case of the vehicle equipped with AVH.
Reset condition
  • Turn ignition switch off and on.
Remarks
  • Buzzer can be on when the charged pressure is not enough.