Open or Short Check

  1. Turn "OFF" the ignition switch.
  2. Disconnect IBAU and EPB ECU connector.
  3. Measure resistance between ground terminal of the EPB ECU harness connector and chassis ground.

    Specification:  Approx. below 1Ω

  4. Is the measured value within specifications?

    YES 

    NO