Open or Short Check
- Turn "OFF" the ignition switch.
- Disconnect IBAU and EPB ECU connector.
- Measure resistance between ground terminal of the EPB ECU harness connector and chassis ground.
Specification: Approx. below 1Ω
- Is the measured value within specifications?
YES
- Go to "C-CAN COMMUNICATION CIRCUIT INSPECTION " procedure.
NO
- Repair short or open in ground circuit between the EPB ECU harness connector and chassis ground and then, go to "VERIFICATION OF VEHICLE REPAIR ".