Monitor GDS Data
- Connect GDS to Data Link Connector (DLC).
- ENG "ON".
- Monitor the "Yaw rate" parameters on the GDS. (SRS current data)
Specification: Approx. 0G
- Is parameter displayed within specifications?
YES
- Go to "WIRING INSPECTION " procedure.
NO
- When Yaw rate sensor output not available signal, check the SRS SYSTEM. and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.