DTC Information And Inspection: DTC Detecting Condition
WARNING: This page is about a different variant/trim than selected.
| Troubleshooting |
Condition |
Possible Cause |
| Main Action |
- Monitor the switch signal
|
- EPB switch circuit open/short circuit
- Faulty EPB switch
- Driver's abnormal switch control (Too many activation, pull or push for long time or slowly push/pull switch)
|
| Threshold Value |
- When the switch input signal does not match any of Neutral, Apply and Release more than 2 seconds
|
| MIL |
- EPB warning lamp is activated
|
| Reset Condition |
- When the EPB switch normal signal is inputted once for each Apply, Release, Neutral value in the same ignition cycle or after ignition switch turned OFF and back ON
|