IU or WU Charging Method
WARNING: This page is about a different variant/trim than selected.
IU or WU Charging Voltage: 14.7V [20°C - 30°C (68°F - 86°F)]
Minimum Charging Voltage [Approx. 24 hr 20°C (68°F)]: 14.4V
Max Charging Voltage [20°C (68°F)]: 14.8V
Recommend 10% capacity of charging current (ex 60Ah: 100% = Charging current 6.0A)
WARNING:
- Do not charge the battery higher than 15.2 voltage, and rapid charge.
- Do not open or remove the AGM battery upper cover.
NOTE:
- If the battery sensor is connected to the battery during the AGM battery charging, the battery sensor may not detect the battery condition, causing a DTC code or malfunction of the AMS function, so using the battery after about 10 hr at room temperature.