| Main action |
|
- Open or short in CAN lines
- Poor connector connection
- Other ECUs incorrectly occupy the CAN Bus line
- Faulty SCC
- Incorrect Controller's version
|
| Threshold value |
- When SCC message's Alive counter does not increase more than 200 milliseconds.
- When SCC messages's request value fault is received for more than 500 milliseconds during control status or for more than 1500 milliseconds during non-control status.
- When received SCC message's checksum value and calculated checksum value is different more than 200 milliseconds during control/non-control status.
|
| Diagnosis time |
- 200 milliseconds/500 milliseconds/1500 milliseconds
|
| MIL |
|
| Reset condition |
- When the normal signal is sent after ignition switch turned OFF and back ON.
|