LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2018 >> Kona Limited, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 156 (Integrated Gateway Power Module Diagnosis) >> DTC B2610-00: Backup Lamp Short Circuit To Ground >> Wiring Inspection >> Power Circuit Inspection

Power Circuit Inspection

WARNING: This page is about a different car, the 2021 Hyundai Kona. However, it is still accessible from the selected car via links, so may be relevant.
Item Normal Value Prerequisite Condition (+) Probe ↔ (-) Probe
Power Circuit Short: Resistance Infinity (∞) 1. Ignition Switch: OFF
2. BATTERY (-) terminal. SJB*, Backup Lamp* connector: Disconnect
Backup Lamp*_Power ↔ Chassis Ground
  1. Is the resistance within specification?

    YES 

    • Check for an intermittent Short-to-Ground caused by bending, corrosion, contamination, deterioration of the harness/connector.

    NO 

    • Repair Short between the Backup Lamp* Power Circuit and Chassis Ground.
    NOTE: SJB*: "IGPM_IPS2 (1CH)"
    Backup Lamp*: "REAR BUMPER LAMP RH_BACK UP LAMP", "REAR BUMPER LAMP LH_BACK UP LAMP"