Shift Control Solenoid Valve B (2-6/B) Resistance Inspection
WARNING: This page is about a different car, the 2021 Hyundai Kona. However, it is still accessible from the selected car via links, so may be relevant.
| Item | Normal Value | Prerequisite Condition | Probe (+) | Probe (-) |
|---|---|---|---|---|
| Solenoid Valve (Open): Resistance | Approx. 5.4Ω (77°F/25°) |
|
Solenoid Power2 Terminal (Component Side) | SCSV-B Control Terminal (Component Side) |
- Is the measured value within specification?
YES
- Replace the PCM/TCM with an usable one and check for proper operation. If it works properly, put the component in place. Then, go to "VERIFICATION OF VEHICLE REPAIR ".
NO
- Replace the Shift Control Solenoid Valve B (2-6/B) with an usable one and check for proper operation. If it works properly, put the component in place. Then, go to "VERIFICATION OF VEHICLE REPAIR ".