LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2018 >> Kona Limited, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 119 (Charging System - 1.6L) >> Battery >> Repair Procedures >> Inspection >> Battery Test Procedure

Battery Test Procedure

WARNING: This page is about a different car, the 2021 Hyundai Kona. However, it is still accessible from the selected car via links, so may be relevant.
  1. Connect the tester to the battery.
    • Red clamp to battery positive (+) terminal.
    • Black clamp to battery negative (-) terminal.
      G12596437Courtesy of HYUNDAI MOTOR AMERICA
      CAUTION:
      • Connect clamps securely. If "CHECK CONNECTION" message is displayed on the screen, reconnect clamps securely.
  2. The tester will ask if the battery is connected "IN-VEHICLE" or "OUT-OF-VEHICLE". Make your selection by pressing the arrow buttons; then press ENTER.
    G12596438Courtesy of HYUNDAI MOTOR AMERICA
  3. Select CCA and press the ENTER button.
    G12596439Courtesy of HYUNDAI MOTOR AMERICA
    NOTE:
    • CCA: Cold cranking amps, is an SAE specification for cranking battered at -0.4°F (-18°C).
  4. Set the CCA value displayed on the screen to the CCA value marked on the battery label by pressing up and down buttons and press ENTER.
    G12596440Courtesy of HYUNDAI MOTOR AMERICA
    NOTE:
    • The battery ratings (CCA) displayed on the tester must be identical to the ratings marked on battery label.
  5. The tester will conduct battery test.
    G12596441Courtesy of HYUNDAI MOTOR AMERICA
  6. The tester displays battery test results including voltage and battery ratings.

    Refer to the following table and take the appropriate action as recommended by the Micro 570.

    G12596442Courtesy of HYUNDAI MOTOR AMERICA

    Battery Test Results 

    BATTERY TEST RESULT

    Result On Printer Remedy
    GOOD BATTERY No action is required.
    GOOD RECHARGE Battery is in a good state.
    Recharge the battery and use.
    You have to follow instruction below when you charge battery and retest, otherwise test result can be inaccurate. (See "Charge and Retest method after battery charge" below.)
    CHARGE & RETEST Battery is not charged properly.
    • Charge and test the battery again.

    You have to follow instruction below when you charge battery and retest, otherwise test result can be inaccurate. (See "Charge and Retest method after battery charge" below.)
    REPLACE BATTERY Replace battery and recheck the charging system.
    • Improper connection between battery and vehicle cables may cause "REPLACE BATTERY". Retest the battery after removing cables and connecting the tester to the battery terminal directly prior to replacing the battery.
    BAD CELL-REPLACE Charge and retest the battery.
    • If the Micro 570 recommends "REPLACE BATTERY", replace the battery and recheck the charging system.

    [Charge And Retest Method After Battery Charge] 

    Battery Charge 

    Set battery charger to "Auto Mode" (The Mode that charging current drops as the battery charges.) and charge battery until charging current down close to zero or the charger alerts you with an alarm when charge is complete.

    (Minimum charging time recommended: More than 3 hours with Auto Mode that explained above)

    • If battery is not fully charged, battery surface voltage will be high while the amount of current charged (CCA) in battery is low. If you measure the battery under this condition, tester may misjudge that battery suffusion occurred because the amount of current in battery is too low in comparison with battery voltage.

      * Surface voltage: When battery is charged electrolyte temperature increases and chemical reaction become active resulting in an excessive increase of battery voltage.

      It is known that it takes approximate one day to subside this increased surface voltage completely.

    Battery Test After Charge 

    Do not test battery right after the charge. Test battery after battery surface voltage has subsided as instructed in the following procedure.

    1. When battery charge is complete, install the battery in the vehicle.
    2. Put IG key to ON position and turn on head lamp with low beam, and wait 5 minutes. (Discharge for 5 minutes)
    3. Turn off the head lamp and IG key, and wait 5 minutes. (Waiting for 5 minutes)
    4. Remove +, - cable from the battery and test battery.
      WARNING:
      • Whenever filing a claim for battery, the print out of the battery test results must be attached.

    Starter Test Procedure 

  7. After the battery test, press ENTER immediately for the starter test.
    G12596443Courtesy of HYUNDAI MOTOR AMERICA
  8. Start the engine.
    G12596444Courtesy of HYUNDAI MOTOR AMERICA
  9. Cranking voltage and starter test results will be displayed on the screen.

    Refer to the following table and take the appropriate action as recommended by the Micro 570.

    G12596445Courtesy of HYUNDAI MOTOR AMERICA

    Starter Test Results 

    STARTER TEST RESULT

    Result On Printer Remedy
    CRANKING VOLTAGE NORMAL System shows a normal starter draw.
    CRANKING VOLTAGE LOW Cranking voltage is lower than normal level.
    • Check starter.
    CHARGE BATTERY The state of battery charge is too low to test.
    • Charge the battery and retest.
    REPLACE BATTERY Replace battery.
    • If the vehicle is not started though the battery condition of "GOOD BATTERY" is displayed, check wiring for open circuit, battery cable connection, starter and repair or replace as necessary.
    • If the engine does crank, check fuel system.
    NOTE:
    • When testing the vehicle with old diesel engines, the test result will not be favorable if the glow plug is not heated. Conduct the test after warming up the engine for 5 minutes.

    Charging System Test Procedure 

  10. Press ENTER to begin charging system test.
    G12596446Courtesy of HYUNDAI MOTOR AMERICA
  11. The tester displays the actual voltage of alternator.

    Press ENTER to continue.

    G12596447Courtesy of HYUNDAI MOTOR AMERICA
  12. Turn OFF all electrical load and rev engine for 5 seconds with pressing the accelerator pedal. (Follow the instructions on the screen)
    G12596448Courtesy of HYUNDAI MOTOR AMERICA
    G12596449Courtesy of HYUNDAI MOTOR AMERICA
    G12596450Courtesy of HYUNDAI MOTOR AMERICA
  13. The message that engine RPM is detected will be displayed on the screen. Press ENTER to continue.
    G12596451Courtesy of HYUNDAI MOTOR AMERICA
  14. If the Engine RPM is not detected, press ENTER after revving engine.
    G12596452Courtesy of HYUNDAI MOTOR AMERICA
  15. The tester will conduct charging system test during loads off.
    G12596453Courtesy of HYUNDAI MOTOR AMERICA
    G12596454Courtesy of HYUNDAI MOTOR AMERICA
  16. Turn ON electrical loads (air conditioner, lamps, audio and etc.). Press ENTER to continue.
    G12596455Courtesy of HYUNDAI MOTOR AMERICA
  17. The tester will conduct charging system test during loads on.
    G12596456Courtesy of HYUNDAI MOTOR AMERICA
  18. Rev Engine for 5 seconds with pressing the accelerator pedal. (Follow the instructions on the screen)
    G12596457Courtesy of HYUNDAI MOTOR AMERICA
    G12596458Courtesy of HYUNDAI MOTOR AMERICA
    G12596459Courtesy of HYUNDAI MOTOR AMERICA
  19. The message that engine RPM is detected will be displayed on the screen. Press ENTER to continue.
    G12596460Courtesy of HYUNDAI MOTOR AMERICA
  20. If the Engine RPM is not detected, press ENTER after revving engine.
    G12596461Courtesy of HYUNDAI MOTOR AMERICA
  21. Turn OFF electrical loads (air conditioner, lamps, audio and etc.). Turn the engine off.
    G12596462Courtesy of HYUNDAI MOTOR AMERICA
  22. Charging voltage and charging system test results will be displayed on the screen.

    Shut off engine end disconnect the tester clamps from the battery. Refer to the following table and take the appropriate action as recommended by the Micro 570.

    G12596463Courtesy of HYUNDAI MOTOR AMERICA
    G12596464Courtesy of HYUNDAI MOTOR AMERICA
    G12596465Courtesy of HYUNDAI MOTOR AMERICA

    Charging System Test Results 

    CHARGING SYSTEM TEST RESULT

    Result On Printer Remedy
    CHARGING SYSTEM NORMAL/DIODE RIPPLE NORMAL Charging system is normal.
    NO CHARGING VOLTAGE Alternator does not supply charging current to battery.
    • Check belts, connection between alternator and battery and replace belts or cable or alternator as necessary.
    LOW CHARGING VOLTAGE Alternator does not supply charging current to battery and electrical load to system fully.
    • Check belts and alternator and replace as necessary.
    HIGH CHARGING VOLTAGE The voltage from alternator to battery is higher than normal limit during voltage regulating.
    • Check connection and ground and replace regulator as necessary.
    • Check electrolyte level in the battery.
    EXCESS RIPPLE DETECTED One or more diodes in the alternator is not functioning properly.
    • Check alternator mounting and belts and replace as necessary.