Air Bleeding Tool Installation Procedure
CAUTION:
To prevent the brake fluid reservoir tank from being damaged and ensure the safety of worker, set the pressure of the gauge to the standard value before installing the SST.
- Before installing the SST on the vehicle, close the air shut-off valve (A) to adjust the pressure gauge to the standard value.
CAUTION: For safety of worker and correct pressure setting, make sure that the plug (B) is installed correctly.
- After connecting an air hose and opening the air shut-off valve (A), adjust the pressure gauge (B) with to the standard value.
Standard pressure value : 0.3 ~ 0.5MPa (43.5 ~ 72.5psi)
- close the air shut off valve (A) and remove the plug (B).
CAUTION: For safety of worker, make sure that the air shut off valve is closed and remove the plug.
- Remove the brake reservoir tank cap.
- Install the cap (A) of SST (0k585-E8100) on the reservoir tank.
- Make sure the check valve (A) is closed and connect SST (09580-3D100) (A) to the adapter (B).