DTC P0462: Fuel Level Sensor 'A' Circuit Low Input: Specification
WARNING: This page is about a different variant/trim than selected.
Analog Gage
| Float Position | S/F | 8/8 | 7/8 | 6/8 | 5/8 | 4/8 | 3/8 |
|---|---|---|---|---|---|---|---|
| Sender Resistance (Ω) | 15 ± 1 | 20 ± 1.5 | 32 ± 1 | 45 ± 1 | 62 ± 1 | 82 ± 1 | 108 ± 2 |
| Fuel remaining (L) | 68.6 | 65.1 | 57.8 | 50.4 | 43.1 | 35.7 | 28.4 |
| Float Position | 2/8 | 1/8 | Warning | G/E | S/E | ||
| Sender Resistance (Ω) | 142 ± 2 | 188 ± 3 | 233 ± 3 | 255 ± 3 | 300 ± 3 | ||
| Fuel remaining (L) | 21.0 | 13.7 | 8.5 | 6.3 | 3.0 |
Digital Gage
| Float Position | S/F | 16/16 | 15/16 | 14/16 | 13/16 | 12/16 | 11/16 |
|---|---|---|---|---|---|---|---|
| Sender Resistance (Ω) | 15 ± 1 | 20 ± 1 | 26 ± 1 | 32 ± 1.5 | 38 ± 1 | 45 ± 1 | 53 ± 1 |
| Fuel remaining (L) | 68.6 | 65.1 | 61.4 | 57.8 | 54.1 | 50.4 | 46.7 |
| Float Position | 10/16 | 9/16 | 8/16 | 7/16 | 6/16 | 5/16 | 4/16 |
| Sender Resistance (Ω) | 62 ± 1 | 72 ± 2 | 82 ± 2 | 95 ± 2 | 108 ± 2 | 124 ± 2 | 142 ± 2 |
| Fuel remaining (L) | 43.1 | 39.4 | 35.7 | 32.0 | 28.4 | 24.7 | 21.0 |
| Float Position | 3/16 | 2/16 | 1/16 | Warning | G/E | S/E | |
| Sender Resistance (Ω) | 163 ± 2 | 188 ± 3 | 218 | 233 ± 2 | 255 ± 2 | 300 ± 3 | |
| Fuel remaining (L) | 17.3 | 13.7 | 10.0 | 8.5 | 6.3 | 3.0 |