Repair Procedures: Inspection
WARNING: This page is about a different variant/trim than selected.
- Immerse the thermostat in water and gradually heat the water.
- Check the valve opening temperature.
Valve opening temperature: 88°C (190°F)
Full opening temperature: 100°C (212°F)
If the valve opening temperature is not as specified, replace the thermostat.
- Check the valve lift.
Valve lift: 8 mm (0.3 in) or more at 100°C (212°F)
If the valve lift is not as specified, replace the thermostat.