Ground Circuit Inspection
WARNING: This page is about a different variant/trim than selected.
- IG "OFF" and disconnect Fuel Control Module (FCM) connector and Instrument Cluster connector.
- Measure resistance between ground terminal of Fuel Control Module (FCM) harness connector and Fuel ground terminal of Instrument cluster harness connector.
Specification: Below 1 Ω
- Is the measured voltage within specification?
YES
- Go to "COMPONENT INSPECTION " procedure.
NO
- Repair or replace as necessary and then, go to "VERIFICATION OF VEHICLE REPAIR " procedure.