Ground Circuit Inspection
WARNING: This page is about a different variant/trim than selected.
- IG "OFF" and disconnect OTS connector and then IG "ON".
- Measure voltage between signal terminal of OTS harness connector and chassis ground.(Measurement "A")
- Measure voltage between signal and ground terminals of OTS harness connector.(Measurement "B")
Specification: Voltage difference between measurement "A" and "B" is below 200mV.
- Is the measured voltage within specification?
YES
- Go to "Component Inspection" procedure below.
NO
- Repair contact resistance or open in harness and go to "VERIFICATION OF VEHICLE REPAIR " procedure.