Control Circuit Inspection
WARNING: This page is about a different variant/trim than selected.
- IG "OFF"
- Disconnect HO2S connector.
- IG "ON" & Engine "OFF"
- Measure voltage between control terminal of HO2S heater harness connector and chassis ground.
Specification: Approx. 2~3 V
- Is voltage within specification?
YES
- Go to "Component Inspection" procedure below.
NO
- Repair or replace as necessary and go to "VERIFICATION OF VEHICLE REPAIR " procedure.NOTE: HO2S must have a clean air reference to function properly. The air is obtained by way of the sensor wire(s). Do not attempt to repair the wire(s), connector, or the terminals.