  1. Remove the engine cover.
  2. Disconnect the battery negative terminal.
  3. Disconnect the air duct (A).
    Fig 1: Locating Air Duct With Mounting Bolts
    G11986991Courtesy of HYUNDAI MOTOR AMERICA
  4. Remove the air duct and air cleaner assembly.

    Tightening torque 

    Hose clamp bolt:

    2.9 ~ 4.9 N.m (0.3 ~ 0.5 kgf.m, 2.2 ~ 3.6 lb-ft)

    Air cleaner assembly bolts:

    7.8 ~ 9.8 N.m (0.8 ~ 1.0 kgf.m, 5.8 ~ 7.2 lb-ft)

    1. Disconnect the breather hose (A), RCV hose (B), booster vacuum hose (C) and air intake hose (D).
    2. Remove the air cleaner assembly (E).
      Fig 2: Locating Breather Hose, RCV Hose, Booster Vacuum Hose, Air Intake Hose And Air Cleaner Assembly
      G11986992Courtesy of HYUNDAI MOTOR AMERICA
  5. Install in the reverse order of removal.