LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2017 >> Sonata Base >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 10 (Lubrication System - 2.0L (Except HEV)) >> Oil Level Gauge & Pipe >> Repair Procedures >> Removal and Installation

Removal and Installation

WARNING: This page is about a different variant/trim than selected.
  1. Remove the oil level gauge (A).
    Fig 1: Removing Oil Level Gauge
    G11994078Courtesy of HYUNDAI MOTOR AMERICA
  2. Remove the intake manifold.

    (Refer to Intake And Exhaust System - "INTAKE MANIFOLD ")

  3. Remove the oil level pipe (A).

    Tightening torque: 

    7.8 ~ 11.8 N.m (0.8 ~ 1.2 kgf/m, 5.8 ~ 8.7 lb-ft)

    Fig 2: Removing Oil Level Pipe
    G11994079Courtesy of HYUNDAI MOTOR AMERICA
  4. Install in the reverse order of removal.