Repair Procedures: Replacement
WARNING: This page is about a different variant/trim than selected.
- Discharge refrigerant from refrigeration system.
- Replace faulty tube or hose.CAUTION: Cap the open fittings immediately to keep moisture or dirt out of the system.
- Tighten joint of bolt or nut to specified torque.CAUTION: Connections should not be torque tighter than the specified torque.HOSE, TUBE & EXPANSION VALVE TORQUE SPECIFICATIONS
Part tightened N.m kgf.m lb-ft Condenser - Discharge hose 4.9 ~ 5.9 0.5 ~ 0.6 3.6 ~ 4.3 Condenser - Liquid tube Compressor - Discharge hose 4.9 ~ 5.9 0.5 ~ 0.6 3.6 ~ 4.3 Compressor - Suction hose Expansion valve - Evaporator 11.8 ~ 14.7 1.2 ~ 1.5 8.7 ~ 10.9 - Evacuate air in refrigeration system and charge system with refrigerant.
Specified amount: 550 ± 25g (19.4 ± 0.88 oz.)
- Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant.
- Inspect A/C operation.