Repair Procedures: Inspection
WARNING: This page is about a different variant/trim than selected.
- Measure the pressure of high pressure line by measuring voltage output between terminal 1 and 2.
- Inspect the voltage value whether it is sufficient to be regular value or not.
Voltage= 0.00878835 * Pressure + 0.5 [PSIA]
- If the measured voltage value is not within specification, replace the A/C pressure transducer.