General Information: DTC Detecting Condition
WARNING: This page is about a different variant/trim than selected.
| Item |
Detecting Condition |
Possible Cause |
| DTC Strategy |
- Prevent the current value caused by the line faulty of a current sensor
- Prevent the control logic error caused by abnormal current value
|
- Current Sensor
- Poor connection or open in harness between battery module and BMS
- Hybrid Battery Current Sensor
- Faulty BMS ECU
|
| Detecting Method |
- Satisfied with threshold value for more than 5 sec.
|
| Enable Condition |
- Ignition ON Auxiliary battery volts between 9V and 16V
|
| Threshold Value |
- The case of Current sensor value > 210A is more than 5 sec.
|
| DTC Release Condition |
- The case of Current sensor value < 200A is more than 5 sec.
|
| Service Lamp ON Condition |
- In case of 2 time DC (Driving cycle: ST ON ~ IG OFF 2 time)
|
| Service Lamp "OFF" Condition |
- In case of satisfying release condition
|
| Safety Mode |
- Normal High voltage: Main relay ON
- BMS available POWER: Power Directing
|