OPU Terminal Input/Output Signal
WARNING: This page is about a different variant/trim than selected.
OPU CONNECTOR E64A TERMINAL INPUT/OUTPUT REFERENCE
| Pin | Description | Condition | Input/output value | |
|---|---|---|---|---|
| Type | Level | |||
| 1 | Main relay power | IG Off ------ After startup (Disable) ------ After startup (Enable) |
DC Voltage | - ------ Max. 0.5V -------- Battery Voltage |
| 2 | Ground | IG Off ------ IG On |
DC Voltage | - ------ Max. 0.5V |
| 3 | Motor phase power (U) | IG Off ------ After startup (Disable) ------ After startup (Enable) |
PWM | - ------ Max. 0.5V -------- Battery Voltage |
| 4 | Motor phase power (V) | IG Off ------ After startup (Disable) ------ After startup (Enable) |
PWM | - ------ Max. 0.5V -------- Battery Voltage |
| 5 | Motor phase power (W) | IG Off ------ After startup (Disable) ------ After startup (Enable) |
PWM | - ------ Max. 0.5V -------- Battery Voltage |
OPU CONNECTOR E64B TERMINAL INPUT/OUTPUT REFERENCE
| Pin | Description | Condition | Input/output value | |
|---|---|---|---|---|
| Type | Level | |||
| 1 | Battery power (+) | IG Off ------ After startup ------ Startup Off (dark current) |
DC Voltage | Battery Voltage ------ Battery Voltage ------ Max 5mA |
| 2 | Battery power (+) | IG Off ------ After startup ------ Startup off (dark current) |
DC Voltage | Battery Voltage ------ Battery Voltage ------ Max 5mA |
| 3 | CAN Low | IG Off ------ Recessive ------ Dominant |
Pulse | - ------ 2.0 ~ 3.0 V ------ 0.5~2.25 V |
| 4 | OPU status signal | IG Off ------ After startup (Low) ------ After startup (High) |
Pulse | - ------ Max. 1.0V -------- 0V/Battery voltage level 9V < Battery voltage level <16V |
| 5 | Hall sensor ground | IG Off ------ IG On |
DC Voltage | - ------ Max. 0.5V |
| 6 | Hall sensor power (+5V) | IG Off ------ IG On |
DC Voltage | - ------ 5.0V ± 0.5V |
| 7 | IG_Key | IG Off ------ IG On |
DC Voltage | - ------ Battery Voltage |
| 9 | CAN High | IG Off ------ Recessive ------ Dominant |
Pulse | - ------ 2.0 ~ 3.0 V ------ 2.75~4.5 V |
| 11 | Hall signal A | IG Off ------ After startup (Low) ------ After startup (High) |
Pulse | - ------ Max. 0.5V -------- 5.0V ± 0.5V |
| 12 | Main relay operation signal | IG Off ------ After startup (Disable) ------ After startup (Enable) |
DC Voltage | - ------ Battery voltage level -------- Battery voltage level |
| 13 | Ground | IG Off ------ IG On |
DC Voltage | - ------ Max. 0.5V |
| 14 | Ground | IG Off ------ IG On |
DC Voltage | - ------ Max. 0.5V |
| 15 | Motor speed command signal | IG Off ------ After startup (Low) ------ After startup (High) |
Pulse | - ------ Max. 0.5V -------- 0V/Battery voltage level 9V < Battery voltage level <16V |
| 17 | Hall signal B | IG Off ------ After startup (Low) ------ After startup (High) |
Pulse | - ------ Max. 0.5V -------- 5.0V ± 0.5V |
| 18 | Hall signal C | IG Off After startup (Low) ------ After startup (High) |
Pulse | - ------ Max. 0.5V -------- 5.0V ± 0.5V |