Monitor Scantool Data
WARNING: This page is about a different variant/trim than selected.
- Connect scantool to Data Link Connector (DLC).
- Engine "ON".
- Driving 1st speed to 6th speed at D-range.
- Select "Current Data" mode and monitor "Oil pump speed Actual RPM" parameter current value.
Specification: See below data
* OPU may be working or not according to by driving situation and loading condition
- Is Oil pump speed Actual RPM value within specific?
YES
- Fault is intermittent caused by poor contact between PCM/TCM and Sensor, and DTC was not cleared.
Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair as necessary and go to "VERIFICATION VEHICLE REPAIR " procedure.
NO
- Go to "TERMINAL AND CONNECTOR INSPECTION " procedure.
- Fault is intermittent caused by poor contact between PCM/TCM and Sensor, and DTC was not cleared.