General Information: DTC Detecting Condition
WARNING: This page is about a different variant/trim than selected.
| Item |
Detecting Condition |
Possible Cause |
| DTC Strategy |
- Circuit Check/Internal failure of the MCU Check
|
- Drive Motor Phase cable connector.
- Open & short in Drive Motor Phase cable.
- Insulation condition in Drive Motor.
- Faulty MCU (HPCU).
|
| Enable Conditions |
- Ignition ON (SSB LED "BLUE")
- Aux. Battery voltage is between 9V and 16V
|
| Threshold Value |
- A current flowing in one of IGBTs is over 2800A
- A voltage of a power supply for power module is under 9V
- A current wave is sensed as a half-sine wave
- Deviation between measured motor current value and target current value is over 6.5A
- A current flowing in one of the 3 phase power cable of inverter has exceeded upper 450A
|
| Diagnosis Time |
- 7 times within 10sec
- 5-usec
- 500msec
- 500msec
- 3-times within 10sec
|
| DTC |
|
| MIL On Condition |
|
| Service Lamp On Condition |
|