Repair Procedures: Removal
WARNING: This page is about a different variant/trim than selected.
- Loosen the drain plug (A), and drain the inverter coolant. Remove the inverter reservoir cap to help drain the coolant faster.
- Disconnect the reservoir inlet hose (A) and outlet hose and pipe assembly (B), then remove the reservoir (C).
Tightening torque: 3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~ 4.3 lb-ft)
- Installation is the reverse of removal.
- Fill the reservoir with coolant and check for leaks.NOTE: Bleed air from the hybrid motor cooling system using GDS. (Refer to "COOLANT ")