Air Bleeding Tool Installation Procedure
WARNING: This page is about a different variant/trim than selected.
CAUTION:
To prevent the brake fluid reservoir tank from being damaged and ensure the safety of worker, set the pressure of the gauge to the standard value before installing the SST.
- Before installing the SST on the vehicle, close the air shut-off valve (A) to adjust the pressure gauge to the standard value.
CAUTION: For safety of worker and correct pressure setting, make sure that the plug (B) is installed correctly.
- After connecting an air hose and opening the air shut-off valve (A), adjust the pressure gauge (B) with the pressure adjuster (C) to the standard value.
Standard pressure value: 0.3 ~ 0.35 MPa (43.5 ~ 50.7 psi)
- Remove the brake reservoir tank cap.
- Install the cap (A) of SST (09580-3D100) on the reservoir tank.
NOTE: Before using the SST adapter, fill up the reservoir tank with brake fluid.
- Fix the adapter to the master cylinder with a SST adapter wire (A).
- Make sure the check valve (A) is closed, remove the plug from the SST hose and connect it to the adapter (B).