General Information: DTC Detecting Condition
WARNING: This page is about a different variant/trim than selected.
| Item |
Detecting Condition |
Possible Cause |
| DTC Strategy |
|
- Open or short of power supply circuit
- Faulty AHB ECU
|
| Case 1 |
Enable Conditions |
- If the valve relay is switched ON and voltage of valve relay < 6 ± 0.5V continuously for 100ms, the failure is detected.
|
| Fail Safe |
- EBD warning lamp and buzzer are activated.
- "Stop! Check Brake!" message is displayed on LCD.
|
| Case 2 |
Enable Conditions |
- If the valve relay is switched OFF and voltage of valve relay > 6 ± 0.5V continuously for 100msec
|
| Fail Safe |
- EBD warning lamp is activated and buzzer is not activated.
- "Check Brake!" message is displayed on LCD.
|