Inspect Glass Alignment
- Check for abnormal noise or bending during operation.
- With the sunroof fully closed, check for water leakage.
- The roof panel (A) should be even with the glass (B) weatherstrip, to within the standard value "E" all the way around. If not, make the following adjustment.
Tightening torque:
Standard value "E" [mm (in.)]
- Front edge : 1.0 ± 1.0mm (0.0394 ± 0.0394 in.)
- Rear edge : 1.0 ± 1.0mm (0.0394 ± 0.0394 in.)
- Side edge :0 ± 1.0mm (0 ± 0.0394 in.)
- If the position is not as specified, lightly loosen the glass adjusting screws (A) to adjust the glass height and tighten it.