Accent, Elantra & Tiburon
Power for radiator fan motor is supplied through radiator fan relay from fusible link in engine compartment fuse/relay box. Radiator fan relay coil power is supplied through engine control relay. Ground circuit for radiator fan relay coil is controlled by PCM. Ensure fan motor rotates when battery voltage is applied between fan motor connector terminals. See WIRING DIAGRAMS . Ensure abnormal noises are not present while motor is running.