Circuit/System Testing
NOTE:
If equipped, the following tests can be performed at an inline connector. See schematics for the corresponding terminals to test at.
- Ignition OFF, disconnect the harness connector at the fuel level sensor.
- Ignition OFF, test for less than 1 Ω between the low reference circuit terminal C and ground.
- If greater than the specified range, test the low reference circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
- Ignition ON, install a 3 A fused jumper wire between the signal circuit terminal B and the low reference circuit terminal C. Verify the scan tool Fuel Tank Level Remaining or the Fuel Level Sensor parameter display is greater than 98 percent.
- If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the fuel level sensor.