Fuel Gage
The instrument panel cluster (IPC) displays the fuel level as determined by the engine control module (ECM). The IPC receives a serial data message from the BCM indicating the fuel level percent. The fuel gage defaults to empty if:
- The ECM detects a malfunction in the fuel level sensor circuit.
- The IPC detects a loss of serial data communications with the BCM.
- The BCM detects a loss of serial data communications with the ECM.