Conditions for Running the DTC
P0722
- No ISS DTC P0717.
- No OSS DTC P0723.
- The selected range is not PARK or NEUTRAL.
- The vehicle speed is greater than 16 km/h (10 mph).
- The transmission input speed is between 1,500-5,000 RPM.
- The engine speed is between 3,000-5,000 RPM.
- The calculated throttle position is greater than 8 percent.
P0723
- No ISS DTCs P0716 or P0717.
- No OSS DTC P0722.
- The engine run time is greater than 5 seconds.
- Greater than 6 seconds since last range change.