Conditions for Setting the DTC: Notes
P0667 - Condition 1
- Vehicle speed is greater than 8 km/h (5 mph) for 300 seconds cumulative.
- Torque converter clutch (TCC) slip speed is greater than 120 RPM for 300 seconds cumulative.
- The TCM internal temperature is between -55°C and +21°C (-67°F and +70°F).
- The TCM internal temperature has changed by less than 2.0°C (3.6°F) in 100 seconds.
- The transmission fluid temperature (TFT) is greater than 70°C (158°F).
- The TFT has increased by 55°C (99°F) since startup.
P0667 - Condition 2
- Vehicle speed is greater than 8 km/h (5 mph) for 300 seconds cumulative.
- TCC slip speed is greater than 120 RPM for 300 seconds cumulative.
- The TCM internal temperature is between 120-150°C (248-302°F).
- The TCM internal temperature has changed by less than 2.0°C (3.6°F) in 100 seconds.
- The TFT is greater than 70°C (158°F).
- The TFT has increased by 55°C (99°F) since startup.