Circuit/System Testing
- The inflatable restraint I/P module disable switch
- The SDM
- The inflatable restraint I/P module wiring harness connector
- The SDM wiring harness connector
- Ignition OFF, disconnect the harness connector at the inflatable restraint I/P module disable switch.
- Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal B and ground.
- If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance, if the circuit tests normal and the ignition fuse is open, test or replace the inflatable restraint I/P module disable switch.
- Verify that a test lamp illuminates between the I/P module disable switch signal control circuit terminal E and B+.
- If the test lamp does not illuminate, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the SDM.
- Verify that a test lamp illuminates between the I/P module suppression indicator control (OFF) circuit terminal A and B+.
- If all circuits test normal, test or replace the inflatable restraint I/P module disable switch.
IMPORTANT:
When removing connectors inspect for damage or corrosion. Damage or corrosion in the following requires repair or replacement of the affected component/connector.