Removal Procedure
- Recover the refrigerant. Refer to Refrigerant Recovery and Recharging .
- Disconnect the electrical connector from the A/C low pressure switch.
- Remove the compressor hose nut from the accumulator.
- Remove the compressor hose from the accumulator.
Courtesy of GENERAL MOTORS CORP.
- Remove the nut (2) from the evaporator fitting.
- Remove the accumulator bracket nut (4) from the retaining stud.
- Remove the accumulator (3).
- Remove the retaining bracket bolt (5).
- Remove the retaining bracket (6) from the accumulator (3).
- Remove and discard the O-ring seals.