LEMON Manuals: Even more car manuals for everyone
Home >> Hummer >> 2008 >> H2 4D Utility Wagon >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC - Automatic >> Diagnostic Information and Procedures >> Auxiliary Blower Motor Malfunction >> Circuit/System Testing

Circuit/System Testing

  1. Ignition OFF, disconnect the X2 harness connector at the auxiliary blower motor control module.
  2. Ignition OFF, test for less than 1 ohm of resistance between the ground circuit terminal 5 and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 6 and ground.
    • If the test lamp does not illuminate, test the B+ circuit for an open/high resistance.
  4. Test for the following voltages between the signal circuit terminal 3 and ground with the auxiliary blower motor speed set at the specified levels:
    • Off-Less than 1 volt
    • Level 1-0.5-8.5 volts
    • Level 2-8.5-9.5 volts
    • Level 3-9.5-10.5 volts
    • Level 4-10.5-11.5 volts
    • If less than the specified range, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
    • If greater than the specified range, test the control circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module.
  5. Reconnect the X2 harness connector at the auxiliary blower motor control module. Disconnect the harness connector at the auxiliary blower motor.
  6. Verify that a test lamp illuminates between the B+ circuit terminal A and ground.
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the Auxiliary Blower Motor Control Module.
  7. Install a test lamp between the B+ circuit terminal A and the low reference circuit terminal B.
  8. While monitoring the test lamp, cycle the auxiliary blower motor through the various speeds. The test lamp should not illuminate with the auxiliary blower motor in the OFF position and become progressively brighter as the auxiliary blower motor speed is increased.
    • If the test lamp is ON with the auxiliary blower motor in the OFF position, test the low reference circuit terminal B for a short to ground. If the circuit tests normal, replace the auxiliary blower motor control module.
    • If the test lamp is always OFF, test the low reference circuit terminal B for a short to voltage or an open/high resistance. If the circuit tests normal, replace the auxiliary blower motor control module.
    • If the test lamp does not become progressively brighter as the auxiliary blower motor speed is increased, replace the Auxiliary Blower Motor Control Module.
  9. If all circuits test normal, test or replace the auxiliary blower motor.