LEMON Manuals: Even more car manuals for everyone
Home >> Hummer >> 2008 >> H2 4D Utility Wagon >> Repair and Diagnosis >> External Pages >> Different car >> Section 94 (HVAC System - Manual) >> Diagnostic Information and Procedures >> Auxiliary Blower Motor Malfunction >> Circuit/System Testing

Circuit/System Testing

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2007 GMC Yukon XL, 2007 GMC Yukon, 2007 Chevrolet Tahoe, 2007 Chevrolet Suburban, and 2007 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF, disconnect the harness connector at the auxiliary blower motor control module.
  2. Ignition OFF, test for less than 1.0 ohm of resistance between the ground circuit and ground.
    • If greater than 1.0 ohm, test the ground circuit for an open/high resistance.
  3. Ignition ON, test for B+ between the battery positive voltage circuit and ground.
    • If less than B+, test the battery positive voltage circuit for a short to ground or an open/high resistance. If the REAR HVAC fuse is open, test battery positive voltage circuit for a short to ground.
  4. With a DMM, test for B+ between the B+ circuit terminal 6 and the control circuit terminal 3.
    • If less than B+, test the control circuit for and open/high resistance. If the circuit tests normal replace the HVAC control module.
  5. Test for 1.5-0.5 ohms of resistance between the low reference terminal 2 and supply voltage terminal 1.
    • If not within specified value, test and replace the auxiliary blower motor.
  6. If all circuits test normal, test and replace the auxiliary blower motor control module.