Front Control: Notes
The HVAC control module controls the distribution of air by the use of recirculation and mode actuators. The modes that may be selected are:
- Defrost
- Defog
- Panel
- BI-Level
- Floor
The mode actuator is connected to the mode door by a cam type linkage system. Depending on the position of the door, air is directed through the HVAC module and distributed through various ducts leading to the outlets in the dash. If a fault is detected within the mode door travel, the HVAC control module will drive the actuator to defrost, which is a default position for the mode door actuator. Turning the mode door position to either defrost or defog positions, the HVAC control module will move the recirculation actuator to outside air reducing window fogging. When defrost/defog is selected, the A/C compressor is activated. The A/C compressor clutch will engage when ambient temperatures are above 3°C (38°F). A/C is available in all modes. Recirculation is only available in Panel and Bi-Level modes. The rear window defogger does not affect the HVAC system.