Circuit/System Description
If a malfunction is detected, a DTC will be stored in non-volatile memory. During a side or frontal crash of sufficient force the inflatable restraint sensing and diagnostic module (SDM) will allow current to flow through the deployment loop in order to deploy the instrument panel (I/P) module. The SDM performs continuous diagnostic tests on the deployment loops to check for proper circuit continuity and for shorts to ground or voltage. There are 2 shorting bars used within the I/P module connector which will short together both I/P module stage 1 high and low circuits, and both I/P module stage 2 high and low circuits, when the connector is disconnected. This will help to prevent unwanted deployment of the inflator module during servicing.