P0AAF and P0AB4 

The hybrid battery pack air temperature sensor 1 or 2 is less than -40°C (-40°F).

P0AAE and P0AB3 

The hybrid battery pack air temperature sensor 1 or 2 is greater than 95°C (203°F).

P0AAD 

The hybrid battery cooling fan is ON and the difference between sensor 1 and 2 is greater than 10°C (50°F) difference for 9 seconds.

P0AB2 

The hybrid battery cooling fan is ON and the outlet air temperature is greater than maximum hybrid battery temperature value by 10°C (50°F) for 9 seconds.