HVAC Control Components

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2012 GMC Yukon XL, 2012 GMC Yukon, 2012 Chevrolet Tahoe, 2012 Chevrolet Suburban, and 2012 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.

The HVAC control module is a GMLAN device that interfaces between the operator and the HVAC system to maintain air temperature and distribution settings. The battery positive voltage circuit provides power that the control module uses for keep alive memory (KAM). If the battery positive voltage circuit loses power, all HVAC DTCs and settings will be erased from KAM. The body control module (BCM), which is the vehicle mode master, provides a device on signal. The control module supports the following features:

Feature Availability
Afterblow Yes
Purge No
Personalization No
Actuator Calibration Yes

Auxiliary HVAC Control Module 

The auxiliary HVAC control module is a GMLAN device that receives analog inputs from the front HVAC control assembly and GMLAN message inputs from the rear seat audio control module to maintain auxiliary air temperature and auxiliary air distribution settings. The battery positive voltage circuit provides power that the control module uses for KAM. If the battery positive voltage circuit loses power, all auxiliary HVAC DTCs and settings will be erased from KAM. The auxiliary HVAC control module will perform a recalibration of the electric actuators when commanded with a scan tool or if KAM is lost. This will ensure the actuators are moving with in the calibrated range.

Rear Seat Audio Control Module 

The rear seat audio control module is a GMLAN device that interfaces between the rear seat passengers and the auxiliary HVAC control module. The battery positive voltage circuit provides power that the control module uses for KAM. Air temperature, blower motor and air delivery rocker type switches are located on the face of the module. Pressing a switch enables the module to send a GMLAN serial data message to the auxiliary HVAC control module for the change request. The module does not store auxiliary HVAC DTCs.

Air Temperature Actuator 

The air temperature actuators are a 5-wire bi-directional electric motor that incorporates a feedback potentiometer. Ignition 3 voltage, low reference, control, 5-volt reference and position signal circuits enable the actuator to operate. The control circuit uses either a 0, 2.5 or 5 volt signal to command the actuator movement. When the actuator is at rest, the control circuit value is 2.5 volts. A 0 or 5-volt control signal commands the actuator movement in opposite directions. When the actuator shaft rotates, the potentiometers adjustable contact changes the door position signal between 0-5 volts.

The HVAC control module uses a range of 0-255 counts to index the actuator position. The door position signal voltage is converted to a 0-255 count range. When the module sets a commanded, or targeted, value, the control signal is changed to either 0 or 5 volts depending upon the direction that the actuator needs to rotate to reach the commanded value. As the actuator shaft rotates the changing position signal is sent to the module. Once the position signal and the commanded value are the same, the module changes the control signal to 2.5 volts.

Auxiliary Air Temperature Actuator 

The auxiliary air temperature actuator is a 5-wire bi-directional electric motor that incorporates a feedback potentiometer. Ignition 3 voltage, low reference, control, 5-volt reference and position signal circuits enable the actuator to operate. The control circuit uses either a 0, 2.5 or 5-volt signal to command the actuator movement. When the actuator is at rest, the control circuit value is 2.5 volts. A 0 or 5-volt control signal commands the actuator movement in opposite directions. When the actuator shaft rotates, the potentiometers adjustable contact changes the door position signal between 0-5 volts. The auxiliary HVAC control module uses a range of 0-255 counts to index the actuator position. The door position signal voltage is converted to a 0-255 count range. When the module sets a commanded, or targeted, value, the control signal is changed to either 0 or 5 volts depending upon the direction that the actuator needs to rotate to reach the commanded value. As the actuator shaft rotates the changing position signal is sent to the module. Once the position signal and the commanded value are the same, the module changes the control signal to 2.5 volts.

Air Temperature Sensor 

The air temperature sensors are a 2-wire negative temperature co-efficient thermistor. The vehicle uses the following air temperature sensors:

A signal and low reference circuit enables the sensor to operate. As the air temperature surrounding the sensor increases, the sensor resistance decreases. The sensor signal voltage decreases as the resistance decreases. The sensor operates within a temperature range between -40 to +101°C (-40 to +215°F). The sensor signal varies between 0-5 volts.

The input of the duct air temperature sensors are different from the ambient and inside air temperature sensors. The HVAC control module converts the signal to a range between 0-255 counts. As the air temperature increases the count value will decrease. If the HVAC control module or auxiliary HVAC control module detects a malfunctioning sensor, then the control module software will use a defaulted air temperature value. The default value for the ambient and inside air temperature sensors will be displayed on the scan tool. The default value for the duct air temperature sensors will not be displayed on the scan tool. The scan tool parameter for the duct air temperature sensors are the actual state of the signal circuit. The default action ensures that the HVAC system can adjust the inside air temperature near the desired temperature until the condition is corrected.

The ambient air temperature sensor mounts underhood and can be affected by city traffic, by idling, and by restarting a hot engine. Therefore, the HVAC control module filters the value of the ambient air temperature sensor for temperature display. The ambient air temperature value is updated under the following conditions:

Condition Display
Engine coolant temperature is less than the ambient air temperature, at start up. Displays real-time temperature
Sensor reading is less than the last displayed value, at start up Displays real-time temperature
At start up with the engine off more than 2 1/2 hours Displays real-time temperature
At start up with the engine off less than 2 1/2 hours Displays last stored temperature
OAT value decreasing. Updates OAT temperature from last stored temperature at a weight factor of 0.25.
Vehicle speed less than 16 km/h (10 mph) and OAT value is increasing. Displays last stored temperature. OAT doesn not update
Vehicle speed greater than 16 km/h (10 mph) and less than 137 km/h (85.6 mph) for atleast 5 minutes and OAT value is increasing. Updates OAT temperature from last stored temperature at a weight factor of 0.01953125
Vehicle speed greater than 137 km/h (85.6 mph) Updates OAT temperature from last stored temperature at a weight factor of 0.01953125

The scan tool has the ability to update the displayed ambient air temperature. To update the ambient air temperature display on the HVAC control module, perform the following procedure: Turn ON the ignition. Simultaneously press the A/C and Recirc switches for 5 seconds.

Evaporator Temperature Sensor 

The evaporator temperature sensor is a 2-wire negative temperature co-efficient thermistor. The sensor operates within a temperature range of -40 to +85°C (-40 to +185°F). The sensor is installed at the evaporator and measures its temperature. If the temperature drops under 3°C (38°F), the compressor will be switched off in order to prevent a frozen evaporator.

Sunload Sensor Assembly 

The sunload sensor is a 2-wire photo diode. The vehicle uses left and right sunload sensors. The 2 sensors are integrated into the sunload sensor assembly. Low reference and signal circuits enable the sensor to operate. As the light shining upon the sensor gets brighter, the sensor resistance increases. The sensor signal decreases as the resistance increases. The sensor operates within an intensity range between completely dark and bright. The sensor signal varies between 0-5 volts. The HVAC control module converts the signal to a range between 0-255 counts. The sunload sensor provides the HVAC control module a measurement of the amount of light shining on the vehicle. Bright, or high intensity, light causes the vehicles inside temperature to increase. The HVAC system compensates for the increased temperature by diverting additional cool air into the vehicle. If the HVAC control module detects a malfunctioning sensor, then the control module software will use a defaulted sunload value. This value will not be displayed on the scan tool. The default action ensures that the HVAC system can adjust the inside air temperature near the desired temperature until the condition is fixed. The scan tool parameter for the sunload sensor is the actual state of the signal circuit.

A/C Refrigerant Pressure Sensor 

The A/C refrigerant pressure sensor is a 3-wire piezoelectric pressure transducer. A 5-volt reference, low reference, and signal circuits enable the sensor to operate. The A/C pressure signal can be between 0-5 volts. When the A/C refrigerant pressure is low, the signal value is near 0 volts. When the A/C refrigerant pressure is high, the signal value is near 5 volts. The powertrain control module (PCM) converts the voltage signal to a pressure value.

The A/C refrigerant pressure sensor protects the A/C system from operating when an excessively high pressure condition exists. The PCM disables the compressor clutch if the A/C pressure is more than 2957 kPa (429 psi). The clutch will be enabled after the pressure decreases to less than 1578 kPa (229 psi).

The A/C low pressure switch protects the A/C system from a low pressure condition that could damage the A/C compressor or cause evaporator icing. The HVAC control module applies 12 volts to the A/C low pressure switch signal circuit. The switch will open when the A/C low side pressure reaches 151 kPa (22 psi). This prevents the A/C compressor from operating. The switch will then close when A/C low pressure side reaches 275 kPa (40 psi). This enables the A/C compressor to turn back ON.