Circuit/System Description
Daytime Running Lamps without HID
The ambient light sensor is used to monitor outside lighting conditions. The ambient light sensor provides a voltage signal that will vary between 0.2 and 4.9 V depending on outside lighting conditions. The HVAC control module provides a low reference ground and 5 V reference signal to the ambient light sensor. The body control module (BCM) monitors the ambient light sensor signal circuit to determine if outside lighting conditions are correct for either daytime running lights (DRL) or automatic lamp control (ALC) when the headlamp switch is in the AUTO position. In daylight conditions, the BCM will command the low beam headlamps ON. Any function or condition that turns on the headlamps will cancel DRL operation.
Daytime Running Lamps with HID
The ambient light sensor is used to monitor outside lighting conditions. The ambient light sensor provides a voltage signal that will vary between 0.2 and 4.9 V depending on outside lighting conditions. The HVAC control module provides a low reference ground and 5 V reference signal to the ambient light sensor. The body control module (BCM) monitors the ambient light sensor signal circuit to determine if outside lighting conditions are correct for either daytime running lights (DRL) or automatic lamp control (ALC) when the headlamp switch is in the AUTO position. In daylight conditions, the BCM will command the DRLs ON by applying ground to the DRL relay control circuits. When the BCM applies ground to the relay control circuit, the DRL relay coil energizes causing the switch contacts to close. With the DRL relay switch contacts closed, battery voltage flows through the DRL fuse to the left and right DRL lamps. Any function or condition that turns on the headlamps will cancel DRL operation.