Conditions for Setting the DTC
P0ADB
The drive motor generator battery control module compares the contactor control circuit to the drive motor generator battery control modules internal 12 V measurement reference circuit. This DTC sets when the contactor control circuit voltage is 2 V less than the drive motor generator battery control module internal voltage reference when the high voltage positive contactor is commanded closed.
P0ADC
The drive motor generator battery control module compares the contactor control circuit to the drive motor generator battery control modules internal 12 V measurement reference circuit. This DTC sets when the contactor control circuit voltage and the drive motor generator battery control modules internal voltage reference are within 2 V of each other when the high voltage positive contactor is commanded open.