  1. Measure actual outside air temperature using a thermometer. Compare this value to the scan tool Outside Air Temp. Raw parameter. The measured temperature should be within 5 degrees of parameter.
    • If not within the specified range, refer to Ambient / Inside Air Temperature Sensor Circuit Malfunction below.
  2. Measure actual inside air temperature using a thermometer. Compare this value to the scan tool Inside Air Temp. Sensor parameter and Aux. Inside Air Temp. parameter. The measured temperature should be within 5 degrees of parameter.
    • If not within the specified range, refer to Ambient / Inside Air Temperature Sensor Circuit Malfunction below.
  3. Measure actual temperature using a thermometer at each of the duct temperature sensors. Compare this value to the appropriate scan tool Duct Actual parameter. The measured temperature should be within 5 degrees of appropriate Duct Actual parameter.